{"product_id":"acuson-sc2000-prime-ultrasound-system-siemenssc2000prime","title":"ACUSON SC2000 PRIME Ultrasound System - siemenssc2000prime","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision at the Speed of Life\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eACUSON SC2000 PRIME \u003c\/strong\u003eis an advanced cardiovascular ultrasound system designed to provide workflow efficiency and precision at every step of the care pathway. It offers a complete Structural Heart Disease solution with a full suite of imaging options and 1-click AI-powered applications, enabling clinicians to handle a wide range of cardiovascular imaging needs. The system integrates speed and precision with connected solutions of the ARTIS fluoroscopy systems, enhancing its utility in structural heart procedures\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInFocus Coherent Technology\u003c\/strong\u003e: Synthesizes every pixel and depth throughout the entire field of view, providing excellent spatial resolution and precise border definition without compromising frame rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue Fidelity Color Doppler\u003c\/strong\u003e: Offers increased sensitivity and specificity of color flow, reducing color artifacts and tissue overwrite for accurate visualization of flow size, direction, and velocity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeSie Valves Advanced Analysis Package\u003c\/strong\u003e: Improves assessment and planning of valvular heart disease patients with dynamic and static modeling and measurements for both the aortic and mitral valves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeSie Measure\u003c\/strong\u003e: AI-powered, 1-click automated measurements that save up to 6 minutes per routine echo exam, reduce hand movements by 30%, and decrease measurement variability by 27%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrueFusion Echo-Fluoro Guidance\u003c\/strong\u003e: Supports reduced contrast dose and shorter procedure times with improved communication and precise targeting through live image overlay.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay\u003c\/strong\u003e: High-resolution monitor for detailed image visualization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Support\u003c\/strong\u003e: Compatible with a wide range of transducers, including 2D and 4D TTE, TEE, and ICE transducers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImaging Modes\u003c\/strong\u003e: Supports 2D, 3D\/4D, M-Mode, Color Doppler, Power Doppler, Pulsed Wave Doppler, and Continuous Wave Doppler imaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Management\u003c\/strong\u003e: Integrated system with DICOM connectivity for seamless information sharing and storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Architecture\u003c\/strong\u003e: Built for dependable and unsurpassed imaging performance across clinical applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProbe Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"\" data-end=\"375\" data-start=\"241\"\u003e\u003cstrong data-end=\"264\" data-start=\"241\"\u003eCurved Array Probes\u003c\/strong\u003e\u003cbr data-end=\"267\" data-start=\"264\"\u003e\u003cstrong data-end=\"274\" data-start=\"267\"\u003e6C2\u003c\/strong\u003e: Abdomen, OB\/GYN, Pediatrics, Peripheral Vascular, Renal\u003cbr data-end=\"334\" data-start=\"331\"\u003e\u003cstrong data-end=\"341\" data-start=\"334\"\u003e7C2\u003c\/strong\u003e: Abdomen, OB\/GYN, Pelvis, Renal\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"608\" data-start=\"377\"\u003e\u003cstrong data-end=\"400\" data-start=\"377\"\u003eLinear Array Probes\u003c\/strong\u003e\u003cbr data-end=\"403\" data-start=\"400\"\u003e\u003cstrong data-end=\"410\" data-start=\"403\"\u003e9L4\u003c\/strong\u003e: Small Parts, Vascular, Musculoskeletal, Breast, Thyroid\u003cbr data-end=\"470\" data-start=\"467\"\u003e\u003cstrong data-end=\"478\" data-start=\"470\"\u003e14L5\u003c\/strong\u003e: Small Parts, Vascular, Musculoskeletal, Breast, Thyroid\u003cbr data-end=\"538\" data-start=\"535\"\u003e\u003cstrong data-end=\"549\" data-start=\"538\"\u003e14L5 SP\u003c\/strong\u003e: Small Parts, Vascular, Musculoskeletal, Breast, Thyroid\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"730\" data-start=\"610\"\u003e\u003cstrong data-end=\"633\" data-start=\"610\"\u003ePhased Array Probes\u003c\/strong\u003e\u003cbr data-end=\"636\" data-start=\"633\"\u003e\u003cstrong data-end=\"643\" data-start=\"636\"\u003e4V1\u003c\/strong\u003e: Cardiac, Transcranial Doppler (TCD)\u003cbr data-end=\"683\" data-start=\"680\"\u003e\u003cstrong data-end=\"691\" data-start=\"683\"\u003e4V1c\u003c\/strong\u003e: Cardiac, Transcranial Doppler (TCD)\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"814\" data-start=\"732\"\u003e\u003cstrong data-end=\"753\" data-start=\"732\"\u003eEndocavity Probes\u003c\/strong\u003e\u003cbr data-end=\"756\" data-start=\"753\"\u003e\u003cstrong data-end=\"765\" data-start=\"756\"\u003eEC9-4\u003c\/strong\u003e: OB\/GYN, Urology\u003cbr data-end=\"785\" data-start=\"782\"\u003e\u003cstrong data-end=\"795\" data-start=\"785\"\u003eEV-8C4\u003c\/strong\u003e: OB\/GYN, Urology\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"926\" data-start=\"816\"\u003e\u003cstrong data-end=\"846\" data-start=\"816\"\u003ePencil Probes (CW Doppler)\u003c\/strong\u003e\u003cbr data-end=\"849\" data-start=\"846\"\u003e\u003cstrong data-end=\"856\" data-start=\"849\"\u003eCW2\u003c\/strong\u003e: Cardiac, Peripheral Vascular\u003cbr data-end=\"889\" data-start=\"886\"\u003e\u003cstrong data-end=\"896\" data-start=\"889\"\u003eCW5\u003c\/strong\u003e: Cardiac, Peripheral Vascular\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStructural Heart Disease\u003c\/strong\u003e: Comprehensive imaging and analysis for diagnosis, intervention, and surgery planning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoutine Echocardiography\u003c\/strong\u003e: Efficient and precise assessments of cardiac function and structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterventional Cardiology\u003c\/strong\u003e: Guidance and monitoring during interventional procedures with real-time imaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePediatric Cardiology\u003c\/strong\u003e: Specialized imaging tailored for pediatric cardiac evaluations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the ACUSON SC2000 PRIME enhance workflow efficiency?\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe system's AI-powered applications, such as eSie Measure, provide 1-click automated measurements, reducing examination time and operator variability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the ACUSON SC2000 PRIME suitable for structural heart disease procedures?\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it offers a complete Structural Heart Disease solution with advanced imaging options and integration with ARTIS fluoroscopy systems for enhanced procedural guidance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat imaging technologies improve diagnostic confidence in the ACUSON SC2000 PRIME?\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eInFocus Coherent Technology and True Fidelity Color Doppler provide high-resolution images with accurate flow visualization, supporting precise diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the ACUSON SC2000 PRIME be used for pediatric cardiology?\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the system is designed to handle a wide range of cardiovascular imaging needs, including specialized pediatric cardiac evaluations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does TrueFusion Echo-Fluoro Guidance benefit interventional procedures?\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eIt offers live image overlay, improving communication and precise targeting, which can reduce contrast dose and shorten procedure times.\u003c\/p\u003e","brand":"Heart Medical Store","offers":[{"title":"Default Title","offer_id":49720220025147,"sku":"siemenssc2000prime","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0848\/6649\/8875\/files\/ACUSON_SC2000_PRIME_Ultrasound_System-001.png?v=1772017330","url":"https:\/\/www.heartmedical.com\/products\/acuson-sc2000-prime-ultrasound-system-siemenssc2000prime","provider":"Heart Medical Store","version":"1.0","type":"link"}